Welcome to our comprehensive Laboratory Furniture Installation Guide. Whether you’ve just received your custom-built lab benches, storage cabinets, or complete steel and wood lab systems, this guide is designed to walk you through the installation process from start to finish.
MAX LAB’ s laboratory furniture is engineered for durability, function, and safety, but proper installation is key to ensuring long-term performance. Please read the following instructions carefully before beginning the setup.

What’s Included in Your Shipment
Before you begin, please inspect your delivery and ensure you have received all components:
Steel Frame Structures (legs, support beams, crossbars)
Work Surfaces (phenolic resin, epoxy resin, stainless steel, or wood)
Cabinet Modules (wood or steel drawers and storage units)
Fasteners (screws, bolts, washers, anchors)
Installation Tools (Allen keys, L-wrenches – depending on your order)
Assembly Drawings and Product Labels (match these to your packing list)
Optional Add-ons: sink modules, reagent racks, fume hood frames, etc.
Required Tools (Not Included)
To complete installation, please prepare the following:
Electric drill/screwdriver with bits
Adjustable wrench
Bubble level
Tape measure
Protective gloves
Rubber mallet
Pencil or marker for alignment
Pre-Installation Preparation
Review Layout Plan:
Refer to the provided room layout or CAD drawings. This will help ensure each bench and module is installed in the correct location.
Check Floor Condition:
Make sure the installation surface is level, clean, and free of debris. Concrete or tiled flooring is preferred for heavy-duty lab furniture.
Unpack Components Carefully:
Remove all packaging with care. Do not use sharp blades near finished surfaces to avoid scratches or damage.
Organize Components by Station:
Group the parts for each workstation together. This simplifies the workflow and prevents mix-ups.
Step-by-Step Installation Guide
1. Frame Assembly (Steel Structure)
a. Layout the Leg Assemblies
Position the leg frames in accordance with your layout drawing. Legs should be evenly spaced to support the worktop, typically 900–1200mm apart.
b. Connect Horizontal Beams and Bracing
Using provided bolts and washers, attach horizontal support beams between legs. Crossbars add lateral stability—install them as shown in the assembly drawings.
c. Check Level and Alignment
Use the bubble level to ensure all legs and frames are perfectly vertical and level before tightening bolts.
2. Install Cabinet Bases (Optional)
If your bench includes under-counter storage cabinets:
Place the cabinets between leg structures.
Cabinets are typically freestanding but can be fastened to frame or floor for added security.
Make sure drawers and doors open freely without obstruction.
3. Install Work Surface
Depending on your chosen material:
Position the top surface on the frame or cabinets.
Align flush with the front edge for ergonomic access.
Secure from below using screws or adhesive brackets (as specified).
Lay the surface gently onto the frame.
Fasten with stainless steel bolts or clips to avoid corrosion.
IMPORTANT: Do not overtighten screws. Overcompression can crack resin or deform the frame.
4. Accessory Installation
Mount vertical posts to the rear edge of the workbench.
Attach shelving at desired heights using provided clamps or brackets.
Drop-in sinks should be sealed using chemical-resistant silicone.
Connect plumbing lines (water and drain) using qualified technicians.
c. Power Strips & Fixtures
Mount electrical strips to underside or rear of workbench.
Ensure proper grounding and follow local electrical codes.
5. Final Adjustments & Inspection
Confirm all screws, bolts, and attachments are secure.
Adjust levelers on legs or cabinet bases if required.
Clean all surfaces with a damp cloth to remove dust or fingerprints.
Inspect for scratches or damage; contact our service team if needed.
Safety Tips
Always wear protective gloves during assembly.
Never exceed the recommended weight capacity for benches or racks.
Ensure sinks and power modules are installed by certified professionals.
Keep the area clear of obstructions during assembly to avoid tripping hazards.
Maintenance Recommendations
Wipe down surfaces regularly with a mild detergent.
Avoid using strong acids or solvents unless worktops are chemical-resistant.
Check fasteners every 6 months to ensure structural integrity.
Lubricate drawer slides and hinges annually to maintain smooth operation.
Need Help?
If you encounter any issues during installation, or you want to buy a new lab furniture, we’re here to assist. Contact our technical support team:
Email: ada@maxlabfurniture.com
Phone:+86 132 4232 3168
Tel: +86 020 3881 3639
Whats App: +86 132 4232 3168
Why We Choose to Be Your Lab Furniture Solution Provider, Not Just a Manufacturer
Max Lab Introduction
Electronics Lab Bench vs Chemistry Lab Bench: What You Need to Know
What Is a Pass Box? Types, Features, and How to Choose the Right Transfer Hatch
For Company
Do you provide installation services?
Yes, we offer professional installation services to ensure your laboratory furniture and equipment are set up properly and safely.
For Logistics
What is the lead time?
We usually will start to work after receiving 50% deposit, and as for the exact lead time, it depends on quantity and detailed requirement. We can promise it will be shipped on time as we negotiated.
How do you ensure the safety of items during shipping?
We have 15 years of experience in loading, fragile goods are packed in plywood boxes to ensure that they will not be damaged during transportation.
For After-Sales Support
How can I get technical support for my equipment?
You can contact our technical support team via email or phone for assistance with installation, troubleshooting, or any issues you encounter with your laboratory equipment.
For Customization
Can I make changes to my order once it has been placed?
We offer limited flexibility to make changes to your order after it has been placed. Contact our sales team as soon as possible if you need to make modifications.
Get in touch with us
If you have any comments or good suggestions, please leave us a message; later our professional staff will contact you as soon as possible.
Scan QR Code
MaxLabFurniture
MaxLab Furniture
daihongada
Max Laboratory